| type: |
vkv1-09/400
|
vkv1-12/400
|
vkv1-16/400
|
vkv1-25/400
|
vkv1-30/400
|
|
output current: |
9 A
|
12 A
|
16 A
|
25 A
|
30 A
|
|
max. output current: |
18 A
|
24 A
|
32 A
|
50 A
|
60 A
|
|
max. net fuse: |
10 A
|
16 A
|
16 A
|
25 A
|
35 A
|
|
input voltage: |
3-phase, 400 VAC *
|
||||
|
control voltage: |
230 VAC * (fuse: 6 A)
|
||||
| output voltage: |
0 ... 360 VAC / 0 ... 87 Hz
|
||||
|
pulse rise time: |
< 900 V/µs
|
||||
|
< 500 V/µs with additional filter
|
|||||
| inverter losses: |
ca. 180 W
|
ca. 200 W
|
ca. 250 W
|
ca. 300 W
|
ca. 350 W
|
| for speeds: |
up to 2,5 m/s (optional up to 4 m/s)
|
||||
| speed sensor: |
60 ... 20.000 ppr. (one track, two tracks, HTL, TTL),
optional without sensor |
||||
| dimensions (LxWxH): |
440 mm x 314 mm x 205 mm
|
||||
| enclosure: |
IP 20
|
||||
| ambient temperature: |
0 ... 40 °C / 104°F (nominal operation),
up to 50 °C / 113°F (temporarily) |
||||
| installation: |
vertical
|
||||
| mounting screws: |
4 screws M6 (4 screws 1/4 inch)
|
||||
| weight **: |
19 kg
|
20 kg
|
20 kg
|
21 kg
|
22 kg
|
| parameter setup: |
via Display or PC (RS232)
|
||||
| control mode: |
vector-controlled
|
||||
|
*) ask for other ratings |
|
|
|
**) without brake resistor and input choke
|
|
| typ: |
vkv2-36/400
|
vkv2-43/400
|
vkv2-50/400
|
vkv2-65/400
|
vkv2-72/400
|
|
output current: |
36 A
|
43 A
|
50 A
|
65 A
|
72 A
|
|
max. output current: |
72 A
|
86 A
|
100 A
|
130 A
|
144 A
|
|
max. net fuse |
35 A
|
50 A
|
50 A
|
63 A
|
80 A
|
|
input voltage: |
3-phase, 400 VAC *
|
||||
|
control voltage: |
230 VAC * (fuse: 6 A)
|
||||
| output voltage: |
0 ... 360 VAC / 0 ... 87 Hz
|
||||
|
pulse rise time: |
< 750 V/µs
|
||||
|
< 500 V/µs with additional filter
|
|||||
| inverter losses: |
ca. 400 W
|
ca. 480 W
|
ca. 500 W
|
ca. 600 W
|
ca. 700 W
|
| for speeds: |
up to 2,5 m/s (optional up to 4 m/s)
|
||||
| speed sensor: |
60 ... 20.000 ppr. (one track, two tracks, HTL, TTL), optional without sensor
|
||||
| dimensions (LxWxH): |
440 mm x 314 mm x 205 mm
|
||||
| enclosure: |
IP 20
|
||||
| ambient temperature: |
0 ... 40 °C / 104°F (nominal operation),
up to 50 °C / 113°F (temporarily) |
||||
| installation: |
vertical
|
||||
| mounting screws: |
4 screws M6 (4 screws 1/4 inch)
|
||||
| weight **: |
28 kg
|
32 kg
|
32 kg
|
33 kg
|
34 kg
|
| parameter setup: |
via Display or PC (RS232)
|
||||
| control mode: |
vector-controlled
|
||||
|
*) ask for other ratings |
|
|
|
**) without brake resistor and input choke
|
|
| type: |
vkv3-90/400
|
vkv3-110/400
|
|
|
|
|
output current: |
90 A
|
104 A
|
|
|
|
|
max. output current: |
180 A
|
220 A
|
|
|
|
|
max. net fuse: |
100 A
|
125 A
|
|
|
|
|
input voltage: |
3~ 400 V *
|
||||
|
control voltage: |
230 V * (fuse: 6 A)
|
||||
| output voltage: |
0 ... 360 V / 0 ... 87 Hz
|
||||
|
pulse rise time: |
< 900 V/µs
|
||||
|
< 500 V/µs with additional filter
|
|||||
| inverter losses: |
ca. 900 W
|
ca.
1100 W |
|
|
|
| for speeds: |
bis 2,5 m/s (optional bis 4 m/s)
|
||||
| speed sensor: |
60 ... 20.000 ppr. (one track, two tracks, HTL, TTL),
optional without sensor |
||||
| dimensions (LxWxH): |
830 mm x 314 mm x 255 mm
|
||||
| enclosure: |
IP 20
|
||||
| ambient temperature: |
0 ... 40 °C / 104°F (nominal operation),
up to 50 °C / 113°F (temporarily) |
||||
| installation: |
vertical
|
||||
| mounting screws: |
4 screws M6 (4 screws 1/4 inch)
|
||||
| weight **: |
45 kg
|
50 kg
|
|
|
|
| parameter setup: |
via Display or PC (RS232)
|
||||
| control mode: |
vector-controlled
|
||||
|
*) ask for other ratings |
|
|
|
**) without brake resistor and input choke
|
|