technical data of opto-encoder, type OE...

type:
OE-1
OE-1S
OE-1E
OE-1SE
design:
standard
shielded
sensitivity adjustable
sensitivity adjustable;
shielded
input voltage:
10...20VDC, protected against polarity reversal
input current:
max. 60 mA
sampling rate:
max. 5kHz
ambient temperature:
-10...50°C
weight (without cable):
ca. 60g
cable length *:
ca. 10m
reflecting tape **:
width:10mm in 5/5mm oder 10/10mm grig pattern or 
width 20mm, 2,5/2,5mm grid pattern


*) If the cable length is larger than 10 m use the shielded design. The extension cord is connected via an additional plug
 
**) The division of of the reflecting tape depends on the circumference (e. g. of the hand-wheel). The pulse-count should be 80 ... 150 pulses per revolution (with thyristor controlled devices) and greater than 150 pulses when a frequency inverter is used.

back to the overview